Safety and Biological Effects in MRI
저자
Devashish Shrivastava
출판사
Wiley
facebook twitter email printer
의학
정가
228,000원
판매가
216,000원
적립금
4,320원
발행일
2021-02-08
페이지수
520 Pages
 
ISBN13
 
9781118821305
제본형태
Hardcover
배송비
결제금액이 25,000원 이상 무료배송
배송
해외주문이 필요한 도서입니다. (4~5주소요) 자세한 내용은 페이지하단 배송안내 참조바랍니다.
주문수량
updown
Available at a lower price from other sellers that may not offer free Prime shipping.

In vivo magnetic resonance imaging (MRI) has evolved into a versatile and critical, if not ‘gold standard’, imaging tool with applications ranging from the physical sciences to the clinical ‘-ology’. In addition, there is a vast amount of accumulated but unpublished inside knowledge on what is needed to perform a safe, in vivo MRI. The goal of this comprehensive text, written by an outstanding group of world experts, is to present information about the effect of the MRI environment on the human body, and tools and methods to quantify such effects. By presenting such information all in one place, the expectation is that this book will help everyone interested in the Safety and Biological Effects in MRI find relevant information relatively quickly and know where we stand as a community. The information is expected to improve patient safety in the MR scanners of today, and facilitate developing faster, more powerful, yet safer MR scanners of tomorrow.

This book is arranged in three sections. The first, named ‘Static and Gradient Fields’ (Chapters 1-9), presents the effects of static magnetic field and the gradients of magnetic field, in time and space, on the human body. The second section, named ‘Radiofrequency Fields’ (Chapters 10-30), presents ways to quantify radiofrequency (RF) field induced heating in patients undergoing MRI. The effect of the three fields of MRI environment (i.e. Static Magnetic Field, Time-varying Gradient Magnetic Field, and RF Field) on medical devices, that may be carried into the environment with patients, is also included. Finally, the third section, named ‘Engineering’ (chapters 31-35), presents the basic background engineering information regarding the equipment (i.e. superconducting magnets, gradient coils, and RF coils) that produce the Static Magnetic Field, Time-varying Gradient Magnetic Field, and RF Field.

The book is intended for undergraduate and post-graduate students, engineers, physicists, biologists, clinicians, MR technologists, other healthcare professionals, and everyone else who might be interested in looking into the role of MRI environment on patient safety, as well as those just wishing to update their knowledge of the state of MRI safety. Those, who are learning about MRI or training in magnetic resonance in medicine, will find the book a useful compendium of the current state of the art of the field.

Contributors

Series Preface

Preface

Acknowledgments

Part A: Static and Gradient Fields

1 Static and Low Frequency Electromagnetic Fields and Their Effects in MRIs 3
Zhenyu Zhang and Stuart Feltham

2 Magnetic-field-induced Vertigo in the MR Environment 23
Paul Glover

3 Effects of Magnetic Fields and Field Gradients on Living Cells 33
Jarek Wosik, Martha Villagran, Ahmed Uosef, Rafik M. Ghobrial, John H. Miller Jr., and Malgorzata Kloc

4 Effect of Strong Time-varying Magnetic Field Gradients on Humans 53
John Nyenhuis and David Gross

5 Peripheral Nerve Stimulation Modeling for MRI 67
Mathias Davids, Bastien Guérin, Lothar R. Schad, and Lawrence L. Wald

6 Magnetically Induced Force and Torque on Medical Devices 87
Terry O. Woods

7 A Review of MRI Acoustic Noise and its Potential Impact on Patient and Worker Health 95
Michael C. Steckner

8 Modeling Blood Flow 119
Michael Keith Sharp

9 Effect of Magnetic Field on Blood Flow 133
G.C. Shit and Sreeparna Majee

Part B: Radiofrequency Fields

10 Safety Standards for MRI 161
Michael C. Steckner

11 On the Choice of RF Safety Metric in MRI: Temperature, SAR, or Thermal Dose 173
Devashish Shrivastava

12 RF Coil and MR Safety 181
J. Thomas Vaughan

13 Local SAR Assessment for Multitransmit Systems: A Study on the Peak Local SAR Value as a Function of Magnetic Field Strength 195
Alexander J.E. Raaijmakers and Bart R. Steensma

14 Radio Frequency Safety Assessment for Open Source Pulse Sequence Programming 207
Sairam Geethanath, Julie Kabil, and J. Thomas Vaughan

15 RF Heating Due to a 3T Birdcage Whole-body Transmit Coil in Anesthetized Sheep 219
Samat Turdumamatov, Ça˘gda¸s Oto, Oktay Algın, Hamza Ergüder, and Tahir Malas

16 In Vivo Radiofrequency Heating due to 1.5, 3, and 7 T Whole-body Volume Coils 227
Shuo Song, Ji Chen, Rongxing Zhang, Qiang He, J. Thomas Vaughan, and Devashish Shrivastava

17 Temperature Management and Radiofrequency Heating During Pediatric MRI Scans 239
Stanley Thomas Fricke, Marjean H. Cefaratti, and Andrew Matisoff

18 Failure to Monitor and Maintain Thermal Comfort During an MRI Scan: A Perspective from a Thermal Physiologist Turned Patient 245
Christopher J. Gordon

19 MR Thermometry to Assess Heating Induced by RF Coils Used in MRI 251
Henrik Odéen, John Rock Hadley, Dylan Palomino, Katelynn Stroth, and Dennis L. Parker

20 Heating of RF coil 273
Joseph Murphy-Boesch

21 RF-Induced Heating in Bare and Covered Stainless Steel Rods: Effect of Length, Covering, and Diameter 289
Sunder Rajan, Peter Serano, Joshua Guag, Tayeb Zaidi, Kyoko Fujimoto, Maria Ida Iacono, and Leonardo M. Angelone 

22 On the Development of a Novel Leg Phantom for RF Safety Assessment for Circular Ring External Fixation Devices in 1.5 T 295
Xing Huang and Ji Chen

23 RF Safety of Active Implantable Medical Devices 311
Berk Silemek, Volkan Açıkel, and Ergin Atalar

24 An Analysis of Factors Influencing MRI RF Safety for Patients with AIMDs 333
Jingshen Liu, Jianfeng Zheng, Qingyan Wang, and Ji Chen

25 On Using Fluoroptic Thermometry to Measure Time-varying Temperatures in MRI 345
Devashish Shrivastava, Mykhaylo Nosovskyy, and Charles A. Lemaire

26 On Using Magnetic Resonance Thermometry to Measure ‘Strong’ Spatio-temporal Tissue Temperature Variations and Compute Thermal Dose 351
Devashish Shrivastava

27 The Use and Safety of Iron-Oxide Nanoparticles in MRI and MFH 361
Hattie L. Ring, John C. Bischof, and Michael Garwood

28 Numerical Simulation for MRI RF Coils and Safety 379
Julie M. Kabil and Anand Gopinath

29 Integral Equation Approach to Modeling RF Fields in Human Body in MRI Systems for Safety 399
Anand Gopinath

30 Safety Practices and Protocols in the MR Research Center of the Columbia University in the City of New York 407
Kathleen Durkin, Dania Elder, and David H. Gultekin

Part C: Engineering

31 History, Physics, and Design of Superconducting Magnets for MRI 423
Bruce Breneman

32 Fabrication of Superconducting Magnets for MRI 447
Bruce Breneman

33 Magnet Field Shimming and External Ferromagnetic Influences on the Homogeneity and Site Shielding of Superconducting MRI Magnets 469
Bruce Breneman

34 Gradient Coils 489
Maxim Zaitsev, Philipp Amrein, Feng Jia, and Sebastian Littin

35 RF Coil Construction for MRI 504
J. Thomas Vaughan and Russell Lagore

Index 521

배송안내

당일출고
List
구분 13시 이전 13시 이후
군자도서 당일출고 1일 추가
타사도서 1일 ~ 2일 추가 2일 ~ 3일 추가

고객님께서 급히 필요하신 상품은 별도로 나누어 주문하시면 수령시간이 절약됩니다.

  • - 당일 13시 이전에 주문과 결제가 확인된 주문건에 대해서 당일출고를 진행합니다. (단, 타사도서, 원서 제외되며 군자출판사에서 출간된 도서로 이뤄진 주문건에 한합니다.)
  • - 월요일 ~ 금요일 사이에 출고가 진행되며, 토요일과 일요일, 연휴기간에는 배송업무가 없으므로 구매에 참고 바랍니다.
  • - 도서수령일의 경우 제품이 출고된 후 하루에서 이틀정도 추가되며, 배송시간은 안내가 어렵습니다.
해외원서의 경우

국내에서 재고를 보유한 업체가 없는 경우 해외주문을 해야 하는 상황이 생깁니다.
이 경우 4~5주 안에 공급이 가능하며 현지 출판사 사정에 따라 구입이 어려운 경우 2~3주 안에 공지해 드립니다.
# 재고 유무는 주문 전 사이트 상에서 배송 안내 문구로 구분 가능하며, 필요에 따라 전화 문의 주시면 거래처를 통해 다시 한번 국내재고를 확인해 드립니다.

배송비 안내

  • - 25,000원 이상 구매시 무료배송 (결제금액이 25,000원 미만일 경우 2,500원의 배송료가 자동으로 추가됩니다.
  • - 반품/취소.환불 시 배송비는 최소 무료 배송이 되었을 경우, 처음 발생한 배송비까지 소급 적용될 수 있으며, 상품 하자로 인한 도서 교환시에는 무료로 가능합니다.

반품안내

전자상거래에 의한 소비자보호에 관한 법률에 의거 반품 가능 기간내에는 반품을 요청하실 수 있습니다.

반품가능기간
  • - 단순변심 : 물품 수령 후 14일 이내 (단, 고객님의 요청으로 주문된 해외원서 제외)
교환이나 반품, 환불이 가능한 경우
  • - 주문하신 것과 다른 상품을 받으신 경우
  • - 파본인 상품을 받으신 경우
  • - 배송과정에서 손상된 상품을 받으신 경우
교환이나 반품, 환불이 불가능한 경우
  • - 개봉된 DVD, CD-ROM, 카세트테이프 (단, 배송 중 파손된 상품 제외)
  • - 탐독의 흔적이 있는 경우
  • - 소비자의 실수로 상품이 훼손된 경우
  • - 고객님의 주문으로 수입된 해외 도서인 경우
  • - 수령일로 14일 지난 상품의 경우

반품절차

3일 이내에 알려주세요.
  • - 책을 받으신 3일 이내에 고객센터 031-943-1888 혹은 1:1 문의게시판을 통해 반품의사를 알려주세요.
  • - 도서명과 환불 계좌를 알려주시면 빠른 처리 가능합니다.
  • - 도서는 택배 또는 등기우편으로 보내주시기 바랍니다.
참고
  • - 14일 이내에 교환/반품/환불 받으실 상품이 회수되어야 하며, 반품과 환불의 경우 상품주문시 면제받으셨던 배송비와 반품배송비까지 고객님께서 부담하시게 됩니다.
반품주소

(10881) 경기도 파주시 회동길 338 (서패동 474-1) 군자출판사빌딩 4층

환불방법
  • - 카드결제 시 카드 승인취소절차를 밟게 되며 무통장입금시 현금 환불 혹은 적립금으로 변환 가능합니다.
  • - 반품도서와 함께 주문번호와 환불계좌번호를 알려주시면 빠른 처리 가능합니다.
Total 0
List
No 제목 글쓴이 등록일 상태
상품문의 작성

이 분야의 베스트도서

이 분야의 베스트원서

이 분야의 신간도서